Achievable safety rating Category 4 ENISO13849-1
PLe ENISO13849-1
SIL 3 EN62061/61508
Stop category 0 EN60204-1
Features Dual-channel monitoring PDF-M (as
per EN 60947-5-3)
Cross-connection detection
Automatic restart
Monitoring of external contactors
(EDM)
Safety sensor/operating
mechanism
Emergency stop button
Magnetic switch with coded magnet
Notes The application must be compatible with 
the automatic start-up function.
All examples shown are proposals without
warranty. In any case the operator has to per-
form a safety review of the entire site.
1.1
1.2
1.3
1.4
3.1
3.2
3.3
3.4
4.1
4.2
4.3
4.4
1.1
1.2
1.3
1.4
2.1
2.2
2.3
2.4
3.1
3.2
3.3
3.4
4.1
4.2
4.3
4.4
UR20-PF-O-xDI-SIL UR20-4DO-P
K4
K3
S1 S3
K3 K4
Reset
L+(+24V)
M (0V)
M
K4
K3
Safety door
(closed)
Emergency stop
Example application for dual-channel safety door monitoring with magnetic switch, automatic reset
and emergency stop
1)
 Switchable modules see section4.3
When the emergency stop button is pushed or the safety
door is opened, the PF-O-xDI-SIL switches off the
24V supply for the modules
1)
within the safety segment and
thus also contactors K3 and K4. The failure of a switching
element in the emergency stop button or the safety door as
well as a cross-circuit in their supply lines does not result in
the failure of the emergency stop mechanism and is detect-
ed within the fault-reaction time.
The PF-O-xDI-SIL switches on the 24V supply for the
modules
1)
within the safety segment if:
the emergency stop button is unlocked
and the safety door is closed
and the feedback circuit (NC contacts of K3 and K4) is
closed.
Contactors K3 and K4 are controlled by the PLC and can
switch on as soon as the PF-O-xDI-SIL has switched
on the 24V supply. To reset the system, press the reset but-
ton for 0.1 to 2s after switching on the power supply, even
when automatic reset is used.
7.8 Dual-channel safety door monitoring with magnetic switch, automatic reset and emergency stop