Product Change Notification
Copyright © 2020 Weidmüller Interface GmbH & Co. KG 3 / 6
All rights reserved. Reproduction without permission is prohibited.
• Usage of the second Ethernet port (X2) is not possible yet and will be added in a future firmware update.
• Node-RED: flow size is currently limited to 1 MB.
• Weidmüller products ‘Managed Switch’ are still not supported regarding DHCP handling.
Bug fixes:
• Node-RED: error 502 Bad Gateway after power up is solved.
Known issues:
• Node-RED: installation of additional nodes might fail with error "EACCES: permission denied". A factory reset
solves this issue.
• Node-RED: iodata-out doesn't accept set values when variable is of type TIME.
• Firefox: 'Private Mode' is currently not supported.
• Remove a module after Autoscan operation and the follow up deploy operation fails. A power cycle is
necessary to solve this error.
Version 1.4.1 Hardware Version 01.xx.xx Release date: November, 2019
Information:
• Usage of the second Ethernet port (X2) is not possible yet and will be added in a future firmware update
Bug fixes:
• U-Link: registration lost with message 'The registration is pending' is solved
Known issues:
• Firefox: 'Private Mode' is currently not supported
• Node-RED: iodata-out doesn't accept set values when variable is of type TIME
• Remove a module after Autoscan operation and the follow up deploy operation fails. A power cycle is
necessary to solve this error.
Version 01.04.00 Hardware Version 01.xx.xx Release date: October, 2019
New supported modules:
• Stepper Module UR20-1SM-50W-6DI2DO-P
New features:
• Function block SEL
Information:
• Usage of the second Ethernet port (X2) is not possible yet and will be added in a future firmware update
• During execution of a firmware update procedure a power loss must be prevented.
Known issues:
• U-Link: in rare cases the status 'The registration is pending' might appear. To solve this issue the registration
key has to renewed in the U-Link web portal. Afterwards a power cycle of the device is necessary to initiate a
new registration.
• Firefox: 'Private Mode' is currently not supported
• Cloud-configuration: iodata-out doesn't accept set values when variable is of type TIME
• Remove a module after Autoscan operation and the follow up deploy operation fails. A power cycle is
necessary to solve this error.
Version 01.03.00 Hardware Version 01.xx.xx Release date: September, 2019
New features:
• u-link
• OPC-UA server
• XY-Line Chart for Smart Visu
• Improved support of the visualisation for resistent touch panels
• Improved support of low performance touch panels can be activated by a selective checkbox in the Visu Editor
Information:
• Usage of the second Ethernet port (X2) is not possible yet and will be added in a future firmware update
• During execution of a firmware update procedure a power loss must be prevented.
Bug fixes:
• Fixed loss of RTC system time on reboot.
Known issues: