User Documentation

10.4 Replacing the battery
WARNING
Explosion risk!
Before starting any work, make sure that
there is not a potentially explosive atmos-
phere!
WARNING
Operation of the machine/system can
be disrupted!
In the event of the machine/system being
put into a dangerous state as a result of
the removal of the supply voltage, a
replacement can only be made once the
machine/system is disconnected from the
power!
WARNING
Danger of contact burns!
Only replace the battery when it is not
under load current.
WARNING
Battery may explode if mistreated!
Use of a wrong battery type may cause
re or explosion!
Do not recharge, disassemble or dispose
of in fire.
Use only batteries of the specified type
(see technical data).
ATTENTION
The product can be destroyed by elec-
trostatic discharge!
The components can be destroyed by electro-
static discharge.
Please make sure that persons and work
equipment are sufficiently earthed!
Unlock the connector frame and open it as far as possible
(at least to an angle of 90°).
Opening the connector frame
Remove the battery using tweezers.
Alternatively, push the battery carefully with a screwdriver
from the mounting plate.
Dispose of the battery correctly.
Insert the new battery as shown with the positive termi-
nal to the left.
+
Inserting the battery
68 2604080000/03/08.2020Manual u-control
10 Replacingcomponents | Replacing the battery