User Documentation

Table Of Contents
System overview
System manual
2696790000/02/04.2020
18
Information
To change the IP address of a panel the device must be connected to a
network.
The IP addresses of the I/O modules are set in u-create studio EoE settings
(see online help).
Information
A maximum of 3 handheld terminals can be used simultaneously.
Connection service PC - system components
For a service PC to be able to communicate with additional components, it
must also be located in the machine network. For that, the service PC is ei-
ther connected via a switch or directly to the X1 port of the control and must
get an IP address by the user that is compatible with the network.
Fig.3-3: Service PC in the machine network
3.4 u-control - CPU modules
Designation Performance data Interfaces
UC20-SL2000-
EC
Dual Core A9, 512 MB RAM, 8
GB EMMC
u-remote bus
EtherCAT Master
UC20-SL2000-
EC-CAN
Dual Core A9, 512 MB RAM, 8
GB EMMC
u-remote bus
EtherCAT Master
CANopen interface
For further information, please refer to the u-control manual or the product
catalog (Automation section).