User Documentation

Weidmüller Interface GmbH Co. KG; Klingenbergstraße 16, 32758 Detmold-Germany
Order No
Version:
SAK 4 EP/SW
0128300000
Accessories: Type
partition plate TW SAK4-10 EP/SW 0130100000
end bracket MEW 1/32 0445600000
TS 32/… acc.to IEC 60715
Q 2 SAK4
0336700000
Q 3 SAK4
0336800000
Q 4 SAK4
0336900000
Q 10 SAK4
0368800000
- Type Epoxy resin
CTI
600
V0
SAK 4 EP/SW
550 V
32 A
≤ 40 K / 32 A
32 A
0,4 mΩ
0,5 - 6 m
1,5 - 4 m
0,5 - 6 m
22 - 10 AWG
0,5 - 1,0 Nm
0,5 - 1,0 Nm
12 mm
& CONDITIONS FOR SAFE USE
II 2 GD
Ex eb IIC Gb
- Operating temperature range
- Flammability class to UL 94
-60°C to +160°C (insulating material limit)
Modular Terminal Blocks: SAKH
Terminal rail
Insulation material:
Cross-connection
- Tracking resistance (A) to IEC 60112
- Temperature rise with rated current
- Conductor cross section solid
- Rated current with cross connection
- Rated voltage
- Rated current
- Conductor cross section flexible
- Tightening torque range for cross
connection
- Tightening torque range, terminal screw
- cross section, American Wire Gauge
- Stripping length
INSTALLATION INSTRUCTIONS
Modular TERMINAL Blocks: SAK- Series
TÜV 18 ATEX 8206 U
IECEx TUR 18.0016 U
Notified Body No. of Ex - QA: 0344
Label print on package unit: 0344
Standards:
EN IEC 60079-0:2018 and EN 60079-7:2015 A1:2018
IEC 60079-0: 7th Edition and IEC 60079-7: 5.1th Edition
- Ambient temperature range
- Ambient temperature range -60°C…+90°C (for T4 applications)
- Ambient temperature range
-60°C…+40°C (for T6 applications)
-60°C…+55°C (for T5 applications)
- Ambient temperature range -60°C…+120°C (for T3 applications)
- Conductor cross section stranded
- Contact resistance with rated conductor
Technical data according to IEC/EN 60079-7 (increased safety "eb"):
Version: SAK 4 EP/SW; 13426810 Index: 00 Date: 08.2019
1