User Documentation
Planning
2053260000/05/2015
23
2.7.3  Cable lengths for bre-optic cabling
Determining the cable length of bre-optic cables is more time-consuming and 
dependent on various factors. Put simply, all attenuations that affect the bre-
optic cable run must be lower than the power budget of the active devices.
Power budget   ≥ ∑Attenuation 
connector
+∑ Attenuation 
splices
+∑Attenuation 
cable
 * Cable
length
•   Power budget: difference between the capacity of the output signal of device 
1 and the readable input capacity of device 2 (e.g.: 4 dB with Multimode)
•   Attenuation 
connector
: the attenuation of all connectors of the transmission path 
(depending on the plug type, in each case approx. 0.3 dB)
•   Attenuation 
splices
: the attenuation of all splices along a transmission path (in 
each case approx. 0.1 to 3.0 dB)
•   Attentuation 
cable
: the attenuation of the cable depending on the wavelength of 
the light (e.g.: 1.5 dB/km at 1,300 nm wavelength of a Multimode bre)
•  Cable length: length of the cable in km (e.g.: 1.2 km)
For example, the result could be as follows for the above equation:
4 dB ≥ 2 * 0.3 dB + 2 * 0.1 dB + 1.5 dB/km * 1.2 km = 2.6 dB
→ the cable length ts