2.7.1  Standardised components
Standardised components are divided into quality categories (also Cat.). 
 Standard categories for industrial applications:
•  Category 5 – Parameters specied up to 100 MHz
•  Category 6 – Parameters specied up to 250 MHz
•  Category 6
A
 – Parameters specied up to 500 MHz
The integrated use of components of
•  Category 5  results in  Class D
•  Category 6  results in  Class E
•  Category 6
A
  results in  Class E
A
   When categories are mixed, the following applies: the components 
with the lowest category determine the class of connection or the 
class of the network.
Cable
category
Connector category
Cat. 5 Cat. 5e Cat. 6 Cat. 6
A
Cat. 7 Cat. 7
A
Cat. 5
Class D
1995
Class D
1995
Class D
1995
Class D
1995
Class D
1995
Class D
1995
Cat. 5e
Class D
1995
Class D
2002 
Class D
2002
Class D
2002
Class D
2002
Class D
2002
Cat. 6
Class D
1995
Class D
2002
ClassE ClassE ClassE ClassE
Cat. 6
A
Class D
1995
Class D
2002
ClassE ClassE
A
ClassE
A
ClassE
A
Cat. 7
Class D
1995
Class D
2002
ClassE ClassE
A
Class F Class F
Cat. 7
A
Class D
1995
Class D
2002
ClassE ClassE
A
Class F Class F
A