User Documentation
Planning
2053260000/05/2015
15
2.1.5  Network connection technology
1  Determine the mode of installation.
  •  Cable routes and cable channels
  •  Additional protective measures against mechanical damage
2  Determine the cabling requirements.
  • Standards
  •   Transmission rates: the requirements for shielding and number of wires 
change according to transmission rate.
  •  Cable lengths
   •   Electromagnetic requirements (MICE): the sheath-material and shielding 
requirements depend on these.
3  Determine the connector requirements
  • Standards
   •   Transmission rates: this gives the required connector class (Cat. 5, 6
A
) and 
also the connector type.
  •   Cable requirements: depending on the cable, certain connector 
requirements have to be met (shield connection, external diameter, possible 
wire insulation and wire diameter).
  •   Electromechanical requirements (MICE): this results in the requirements for 
shielding and protection degree.
  • Size
4  Select additional connecting components:
  •  Patch distributor
  •  Media converter
   •  Converter from a solid to exible conductor (e.g., terminal rail outlets)