User Documentation
2053260000/05/2015138
Installation
The connections must feature a high-quality polish. The reference bre may be 
used for no more than 500 reference measurements. Then the connections have 
to be polished again. Please treat the reference bres with great care. After 2,000 
reference measurements, the reference bres should be replaced. Please also 
note the details provided by the manufacturer.
   Only special reference bres may be used to connect the section 
requiring testing.
   The measurement must be taken with the operating wavelength 
used later on and with the transmitter belonging to the 
measurement receiver. The transmitter, receiver and bre type 
should be coordinated.
   The limit values stated for the maximum permitted end-to-end 
link attenuation already contain an attenuation reserve. Do 
however take into account possible measurement inaccuracies 
and the tolerance of your measuring device. These should be 
included in the limit value for the maximum permitted end-to-
end link attenuation.
   Note in particular that the comparably high attenuation of POF 
coupled with several plug-in connectors reduces the maximum 
length of the bre-optic connection.