User Documentation
Title: PROtop IO-Link Register Description
2019.11.29, Page 16/17
DocVersion: 1.1
CIOL - Device Temperature >60°C
0x8CA7
Information
1 bit
Signals, that temperature in at
Communication IO-LINK device
increases a limit of 60°C
Condition:
T > 60°C
CIOL - Device Temperature >70°C
0x8CA8
Warning
Appears/ Disap-
pears
1 bit
Signals, that temperature in at
Communication IO-LINK device
increases a limit of 60°C
Condition:
T > 70°C
CIOL - Device Temperature <-25°C
0x8CA9
Information
1 bit
Signals, that temperature in at
Communication IO-LINK device
decreased a limit of -25°C
Condition:
T < -25°C
CIOL - Device Temperature <-40°C
0x8CAA
Warning
Appears/ Disap-
pears
1 bit
Signals, that temperature in at
Communication IO-LINK device
increases a limit of -40°C
Condition:
T < -40°C
CIOL - Device Failure
0x8CAB
Error
Appears/ Disap-
pears
1 bit
Signals a failure in the Self Test of
a CIOL device.
Condition: See Self Test Func-
tions