User Documentation

Title: PROtop IO-Link Register Description
2019.11.29, Page 14/17
3.3.2 System Commands for PROtop IO-LINK
Table 4: System Commands for PROtop IO-LINK
Command Name
Command Number
Comment/ Description
Combi Restart Command
After the Communication IO-LINK device gets the
command it fulfills a soft restart where the following
steps are executed.
(1) Soft restart of PROtop
(2) Soft restart of the CIOL
CIOL Restart Command
After the Communication IO-LINK device gets the
command it fulfills a soft restart.
PROtop Restart Command
After the PROtop gets the command it fulfills a soft
restart.
PROtop Set Factory Default Command
After the PROtop gets the command it configures its
parameters to the defined default values.
PROtop Save On / Off State Command
After the PROtop gets the command, it saves the
actual value of " PROtop On / Off" into EEPROM of
PROtop to store the state after restart of Power
Supply.
This command is only valid, if PROtop Configuration
Select = 0x01.
PROtop Switch On After Short Circuit
Switch Off
After the PROtop gets the command, it switches the
DC output on after it was switched off after a short
circuit.
PROtop Save Rated Voltage Output Value
Command
After the PROtop gets the command, it saves the
actual value of " PROtop Rated Value Voltage Out-
putinto EEPROM of PROtop to store the value after
restart of Power Supply.
This command is only valid, if PROtop Configuration
Select = 0x01.