User Documentation

192639590000/00/11.2018
7 Troubleshooting
If a fault cannot be resolved by means of the ac-
tions described here, please refer to Weidmüller
Service.
7.1 Fault table
Fault Possible cause Recommended action
LED out Power supply is interrupted Check the power cord and the power
connector.
Check the fuses.
LED ashes Foot switch is not connected Connect foot switch
Foot switch permanently activated Cancel operation
Ferrule falls into the interior of the
machine
Crimp size set incorrectly Remove ferrule
Set suitable crimp size
Ferrule is too small Remove ferrule
Use larger ferrule
Ferrule can not be inserted Crimp size set incorrectly Set suitable crimp size
Ferrule is too big Use smaller ferrule
7.2 Replacing fuses
Make sure that the machine is switched o󰀨.
Remove the power plug.
1
Figure 7.1 Opening the fuse compartment
Lever the fuse compartment (1) out of the mains lter
unit using a slotted screwdriver.
Replace both fuses with new ones (2 x T2AH250V).
Put the fuse compartment back into the mains lter unit.