User Documentation
Wi-Fi device IE-WL-VL-AP-BR-CL  Web Console Configuration 
3-70 
For cases where advanced troubleshooting is required, contact a Weidmüller engineer who can provide you 
with an encrypted script file. The encrypted script file can capture additional details on the system. 
To run the script, browse to and select the script file using Browse and click Run Script after you have filled 
in the following details: 
Setting 
Description 
Diagnostic script 
Use the Browse button to select the Weidmüller diagnosis script file. 
Export diagnostic results 
Select if you want to export: 
-  to a file 
-  to a TFTP server 
TFTP server IP 
If you have selected the TFTP option, specify the IP address of the TFTP server. 
Diagnostic script name 
Displays the name of the script file 
Last start time 
Displays the start time of the last script execution 
Last end time 
Displays the end time of the last script execution 
Diagnostic status 
Displays the progress of the system diagnostics 
Diagnostic result 
Displays the result of the system diagnostics. 
If you have selected the export to a file option, the system log is encrypted and 
packed into a file. The limit on the log file size is 1 MB. When the size of the log file 
reaches 1MB another file is created. A maximum of 5 files (5MB) will be kept for 
downloading. When the number of files exceeds five, the oldest file is deleted. 
Save Configuration 
The following figure shows how the IE-WL-VL-AP-BR-CL stores the setting changes into volatile and 
non-volatile memory. All data stored in volatile memory will disappear when the IE-WL-VL-AP-BR-CL is 
shutdown or rebooted. Because the IE-WL-VL-AP-BR-CL starts up and initializes with the settings stored in 
flash memory, all new changes must be saved to flash memory before restarting the IE-WL-VL-AP-BR-CL. 
This also means the new changes will not work unless you run either the Save Configuration function or the 
Restart function.   