User Documentation
Wi-Fi device IE-WL-VL-AP-BR-CL  Web Console Configuration 
3-55 
Saving configuration to EBR-MODULE 
RS232 
The configuration is successfully saved/there is an error saving the 
configuration to EBR-MODULE RS232. 
EBR-MODULE RS232 failure 
IE-WL-VL-AP-BR-CL cannot detect an EBR-MODULE RS232 at 
the console port. 
Configuration reset to default 
The configuration is reset to factory default. 
Power events 
Event is triggered when…   
Power 1/2 transition (On -> Off)   
The IE-WL-VL-AP-BR-CL is powered down in PWR1/2.  
PoE transition (On -> Off)   
The IE-WL-VL-AP-BR-CL is powered down in PoE.  
Power 1/2 transition (Off -> On) 
The IE-WL-VL-AP-BR-CL is powered via PWR1/2. 
PoE transition (Off -> On) 
The IE-WL-VL-AP-BR-CL is powered via PoE. 
Syslog 
This function provides the event logs for the Syslog server. The function supports up to three configurable 
Syslog servers and Syslog server UDP port numbers. When an event occurs, the event will be sent as a Syslog 
UDP packet to the specified Syslog servers. 
Syslog Event Types 
Detailed information for the grouped events is shown in the following table. Check the box for Enable logging 
to enable the grouped events. All default values are enabled (checked). Detailed descriptions of the event types 
are available in the System Logs section. 
Syslog Server Settings 
You can configure the parameters for your Syslog servers in this page. 
Syslog server 1/ 2/ 3 
Setting 
Description 
Factory Default 
IP address 
Enter the IP address of the 1st/ 2nd/ 3rd Syslog Server 
None 
Syslog port 
Setting 
Description 
Factory Default 
Port destination   
(1 to 65535) 
Enter the UDP port of the corresponding Syslog server 
514 