User Documentation
Wi-Fi device IE-WL-BL-AP-CL  Getting Started 
2-9 
Protocol Support 
General Protocols: Proxy ARP, DNS, HTTP, HTTPS, IP, ICMP, SNTP, TCP, UDP, RADIUS, SNMP, DHCP, LLDP 
Interface 
Default Antennas: 2 dual-band omni-directional antennas, 2 dBi, RP-SMA (male) 
Connector for External Antennas: RP-SMA (female) 
LAN Ports: 1, RJ45, 10/100/1000BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection 
Console Port: RS-232 (RJ45-type) 
Reset: Present 
LED Indicators: PWR, FAULT, STATE, SIGNAL*, WLAN, 10/100/1000 (RJ45 port) 
*signal strength indicator 
Physical Characteristics 
Housing: Metal, IP30 protection 
Weight: 307 g (0.68 lb) 
Dimensions: 58 x 115 x 70 mm (2.29 x 4.53 x 2.76 in) 
Installation: DIN-rail mounting (standard), wall mounting (optional) 
Environmental Limits 
Operating Temperature: 
•  Standard Models: 0 to 60°C (32 to 140°F) 
•  Wide Temp. Models: -40 to 75°C (-40 to 167°F) 
Storage Temperature: -40 to 85°C (-40 to 185°F) 
Ambient Relative Humidity: 5% to 95% (non-condensing) 
Power Requirements 
Input Voltage: 12 to 48 VDC, redundant dual DC power inputs 
Connector: 4-pin removable terminal block, 500 V insulation 
Power Consumption: 6.96 W 
Reverse Polarity Protection: Present 
Standards and Certifications 
Safety: UL 60950-1, EN 60950-1 
EMC: EN 55032/55024 
EMS: 
•  IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV   
•  IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m   
•  IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV   
•  IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV 
•  IEC 61000-4-6 CS: 3 V  
•  IEC 61000-4-8 
Radio: EN 301 489-1/17, EN 300 328, EN 301 893, TELEC, FCC ID SLE-WAPN008, KC, RCM, IC ID 
Note: Please check Weidmüller’s website for the most up-to-date certification status. 
Reliability 
MTBF (mean time between failures) 
Time: 810,022 hrs 
Standard: Telcordia SR332 
Warranty 
Warranty Period: 5 years 
ATTENTION 
•  The IE-WL-BL-AP-CL is NOT a portable mobile device and should be located at least 20 cm away from the 
human body.   
•  The IE-WL-BL-AP-CL is NOT designed for the general public. A well-trained technician should be enlisted 
to ensure safe deployment of IE-WL-BL-AP-CL units, and to establish a wireless network. 