User Documentation
Wi-Fi device IE-WL-BL-AP-CL  Web Console Configuration 
3-53 
4.  IE-WL-BL-AP-CL will detect the EBR-MODULE RS232 during the boot up process, and download the 
configuration from the EBR-MODULE RS232 to the IE-WL-BL-AP-CL automatically. Once the configuration 
downloads and if configuration format is correct, the IE-WL-BL-AP-CL will emit three short beeps and 
continue with the boot-up process. 
5.  Once the IE-WL-BL-AP-CL has booted up successfully, it will emit the normal two beeps, and the ready LED 
will turn to solid green. 
Load Factory Default 
Use this function to reset the IE-WL-BL-AP-CL and rollback all settings to the factory default values. You can 
also reset the hardware by pressing the reset button on the top panel of the IE-WL-BL-AP-CL. 
Account Settings 
To ensure that devices located at remote sites are secure from hackers, we recommend setting up a 
high-strength password the first time you configure the device. 
Field 
Description 
Default setting 
Minimum 
password length 
By default, passwords can be between 4 and 16 characters. For 
improved security, we recommend changing the minimum 
password length to at least 8 characters the first time you 
configure the device. 
4 
Password 
strength check 
Enable the password strength check option to ensure that users 
are required to select high-strength passwords. 
Disable 