User Documentation
Wi-Fi device IE-WL-BL-AP-CL  Web Console Configuration 
3-45 
Syslog server 1/ 2/ 3 
Setting 
Description 
Factory Default 
IP address 
Enter the IP address of the 1st/ 2nd/ 3rd Syslog Server 
None 
Syslog port 
Setting 
Description 
Factory Default 
Port destination   
(1 to 65535) 
Enter the UDP port of the corresponding Syslog server 
514 
NOTE 
RSSI report events (Only for Client mode) event type is useful for the site survey stage. However, this 
function increases the traffic load because it needs to use a special utility to retrieve the RSSI values in a 
tabular format. So, we recommend disabling this function during normal usage. 
E-mail Notifications 
Notification Event Types 
Check the Active box next to the event type to enable the event type for email notification. By default, all event 
types are deactivated (unchecked). 
E-mail Server Settings 
You can set up to 4 e-mail addresses to receive alarm emails from the IE-WL-BL-AP-CL. The following 
parameters can be configured on the E-mail Server Settings page. In addition, a Send Test Mail button can 
be used to test whether the Mail server and e-mail addresses work well. More detailed explanations about these 
parameters are given after the following figure. 
Mail server (SMTP) 
Setting 
Description 
Factory Default 
IP address 
The IP Address of your email server. 
None 