User Documentation
- 13 - 
Power 
Input Voltage 
12 to 48 VDC, redundant dual DC power inputs or 48 
VDC Power-over-Ethernet (IEEE 802.3af) 
Input Current 
0.494A-0.121A (@ 12-48VDC) 
0.3A @24 VDC 
Reverse Polarity 
Protection 
Present 
Mechanical 
Casing 
IP30 protection, aluminum case 
Dimensions 
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in) 
Weight   
850g 
Installation 
DIN-Rail, or wall mounting 
Environmental 
Operating Temperature 
Standard models: 0 to 60°C (32 to 140°F) 
Wide Temp. Models: -40 to 75°C (-40 to 167°F) 
Storage Temperature 
-40 to 85ºC (-40 to 185ºF) 
Ambient Relative Humidity 
5 to 95% (non-condensing) 
Standards and Certifications 
Safety   
UL 60950-1, EN 60950-1 
Hazardous Location 
UL/cUL Class I, Division 2, Groups A, B, C, and D; 
ATEX Zone 2: Ex nA IIC T4 Gc 
EMC 
EN 301 489-1/-17; FCC Part 15, Subpart B; EN 
55022/55024 
Radio 
EN300 328, EN 801 893, TELEC, FCC ID 
SLE-WAPA003 
WARRANTY 
5 years 
Weidmüller gives a 5 year warranty on this product in accordance with 
the warranty terms as described in the general conditions of sale of the 
Weidmüller company which has sold the products to you. Weidmüller 
warrants to you that such products the defects of which have already 
existed at the time when the risk passed will be repaired by Weidmüller 
free of charge or that Weidmüller will provide a new, functionally 
equivalent product to replace the defective one. Safe where expressly 
described otherwise in writing in this catalogue/product description, 
Weidmüller gives no warranty or guarantee as to the interoperability in 
specific systems or as to the fitness for any particular purpose. To the 
extent permitted by law, any claims for damages and reimbursement of 
expenses, based on whatever legal reason, including contract or tort, 
shall be excluded. Where not expressly stated otherwise in this warranty, 
the general conditions of purchase and the expressive liability 
commitments therein of the respective Weidmüller company which has 
sold the products to you shall be applicable. 
ATTENTION 
The IE-WL-AP-BR-CL-ABG is NOT a portable mobile device and should 
be located at least 20 cm away from the human body.   
The IE-WL-AP-BR-CL-ABG is NOT designed for the general public. To 
deploy IE-WL-AP-BR-CL-ABG and establish a wireless network safely, a 
well-trained technician is required for installation. 