User Documentation

IE-WL-AP-BR-CL-ABG Web Console Configuration
3-32
MD5 Provide authentication based on the HMAC-MD5 algorithms.
8-character passwords are the minimum requirement for
authentication.
SHA Provides authentication based on
HMAC-SHA algorithms. 8-character passwords are the
minimum requirement for authentication.
Admin private key (for V1, V2c, V3, and V3 only)
Setting Description Factory Default
Disable No data encryption
DES DES-based data encryption
AES AES-based data encryption
Disable
Private key
A data encryption key is the minimum requirement for data encryption (maximum of 63 characters)
Private MIB Information Device Object ID
Also know as OID. This is the IE-WL-AP-BR-CL-ABG’s enterprise value. It is fixed.
Link Fault Pass-Through (for Client/Slave mode only)
This function means if Ethernet port is link down, wireless connection will be forced to disconnect. Once
Ethernet link is recovered, IE-WL-AP-BR-CL-ABG will try to connect to AP.
If wireless is disconnected, IE-WL-AP-BR-CL-ABG restarts auto-negotiation on Ethernet port but always stays
in the link failure state. Once the wireless connection is recovered, IE-WL-AP-BR-CL-ABG will try to recover the
Ethernet link.
System log will indicate the link fault pass through events in addition to the original link up/down events.
Link Fault Pass-Through
Setting Description Factory Default
Enable Enables Link Fault Pass-Through
Disable Disable Link Fault Pass-Through
Disable
Auto Warning Settings
Since industrial-grade devices are often located at the endpoints of a system, these devices will not always
know what is happening elsewhere on the network. This means that these devices, including wireless APs or
clients, must provide system maintainers with real-time alarm messages. Even when system administrators
are out of the control room for an extended period, they can still be informed of the status of devices almost
instantaneously when exceptions occur.
In addition to logging these events, the IE-WL-AP-BR-CL-ABG supports different approaches to warn engineers
automatically, such as SNMP trap, e-mail, and relay output. It also supports two digital inputs to integrate
sensors into your system to automate alarms by email and relay output.