User Documentation

IE-WL-AP-BR-CL-ABG Web Console Configuration
3-31
requirements for authentication and
encryption.
The following parameters can be configured on the SNMP Agent page. A more detailed explanation of each
parameter is given below the following figure.
Enable
Setting Description Factory Default
Enable Enables SNMP Agent
Disable Disables SNMP Agent
Disable
Remote Management
Setting Description Factory Default
Enable Allow remote management via SNMP agent
Disable Disallow remote management via SNMP agent
Disable
Read community (for V1, V2c)
Setting Description Factory Default
V1, V2c Read
Community
Use a community string match with a maximum of 31
characters for authentication. This means that the SNMP agent
can access all objects with read-only permissions using this
community string.
public
Write community (for V1, V2c)
Setting Description Factory Default
V1, V2c Read /Write
Community
Use a community string match with a maximum of 31
characters for authentication. This means that the SNMP agent
can accesses all objects with read/write permissions using this
community string.
private
SNMP agent version
Setting Description Factory Default
V1, V2c, V3, or
V1, V2c, or
V3 only
Select the SNMP protocol version used to manage the switch. V1, V2c
Admin auth type (for V1, V2c, V3, and V3 only)
Setting Description Factory Default
No Auth Use admin account to access objects. No authentication No Auth