User Documentation
- 13 -
100BaseFX Ethernet Port Connection (Fiber) 
Remember to connect the Tx (transmit) port of device 1 to the Rx (receive) 
port of device 2, and the Rx (receive) port of device 1 to the Tx (transmit) 
port of device 2. Fiber optic connections generally are using the 
full-duplex transmission mode. 
SC-Port Pinouts  SC-Port to SC-Port Cable Wiring 
ST-Port Pinouts  ST-Port to ST-Port Cable Wiring 
ATTENTION
This is a Class 1 Laser/LED product. To avoid causing 
serious damage to your eyes, do not stare directly into the 
Laser Beam. 
DIP Switch Settings 
IE
-
SW
-
VL16
Series
DIP Switches
The default setting for each DIP Switch is OFF. The following table 
explains the effect of setting the DIP Switches to the ON positions.
DIP Switch
Setting
Description
----
–  Serves no function (reserved for future use). 
Port Alarm 
Function 
(P1 to P16)
ON 
Enables the corresponding PORT Alarm. If the 
port’s  link  fails,  the  relay  will  form  an  open 
circuit and the fault LED will light up. 
OFF 
Disables the corresponding 
PORT Alarm. The 
relay  will  form  a  closed  circuit  and  the  Fault 
LED will never light up. 
BSP 
ON 
Enables broadcast storm protection (limitation 
to  2000  broadcast  packets  per  second  and 
port) 
OFF  Disables broadcast storm protection 