Approval/Certificate/Document of Conformity
 [13]
   Schedule 
 [14]   TYPE EXAMINATION CERTIFICATE No. 
   DEMKO 11 ATEX 150191X Rev. 4 
00-IC-F0060-1 – Issue 14.0 
This certificate may only be reproduced in its entirety and without any change, schedule included.  Page 3 of 3  
Electrical data 
Model 
Electrical Rating 
Relay Output 
Protection Method 
Series IE-SW-VL16-16TX 
12-48VDC, 0.6A, 
24VDC, 1A, Resistive 
nA nC  
Series IE-SW-VL16T-16TX 
12-48VDC, 0.6A, 
24VDC, 1A, Resistive 
nA nC 
Series IE-SW-PL16M-16TX 
12-48VDC, 1.6A, 
24VDC, 1A, Resistive 
nA nC 
Series IE-SW-PL16MT-16TX 
12-48VDC, 1.6A, 
24VDC, 1A, Resistive 
nA nC 
Series IE-SW-PL18M-2GC-16TX 
12-48VDC, 1.6A, 
24VDC, 1A, Resistive 
nA nC 
Series IE-SW-PL18MT-2GC-16TX 
12-48VDC, 1.6A, 
24VDC, 1A, Resistive 
nA nC 
For alternate construction 
IE-SW-VL16-16TX, IE-SW-VL16T-
16TX, IE-SW-VL16-14TX-2SC, IE-
SW-VL16T-14TX-2SC, IE-SW-
VL16-14TX-2ST, IE-SW-VL16T-
14TX-2ST 
12/24/48 VDC, 0.86/0.4/0.2A, 
Class 2 
or 
12-48Vdc, 0.86-0.2A, Class 2 or 
12-48Vdc, 0.86A max., Class 2 
or 
12Vdc, 0.86A, Class 2 or 
24Vdc, 0.4A, Class 2 or 48Vdc, 
0.2A, Class 2 
24VDC, 1A, Resistive 
nA nC 
Routine tests: 
No routine tests are necessary. 
 [16]  Descriptive Documents 
The scheduled drawings are listed in the report no. provided under item no. [ 8 ] on page 1 of this Type Examination Certificate. 
 [17]  Special Conditions of Use: 
•  The Ethernet Communication Devices are to be mounted in an ATEX-Certified tool-accessible IP54 enclosure and used in an area of 
not more than pollution degree 2 as defined by EN 60664-1. 
•  Provisions shall be made, either in the equipment or external to the equipment, to provide the transient protection device to be set at 
a level not exceeding 140% of the peak rated voltage. 
 [18]  Essential Health and Safety Requirements 
The Essential Health and Safety Requirements (EHSRs) covered by the standards listed at item 9. 
Additional information 
The trademark   will be used as the company identifier on the marking label. 