Approval/Certificate/Document of Conformity

[13]
Schedule
[14]
TYPE EXAMINATION CERTIFICATE No.
DEMKO 11 ATEX 150188X
Rev. 4
00-IC-F0060-1 – Issue 14.0
This certificate may only be reproduced in its entirety and without any change, schedule included.
Page 2 of 2
[15] Description of Product:
The Models IE-SW-VL09-6TX-3SC and IE-SW-VL09T-6TX-3SC are DIN rail mounted, industrial application, Unmanaged Ethernet
Switches. They are intended for industrial applications, pollution degree 2 environments. They are microcomputer-based and communicate
via interfaces through wire. The models are of the open type and are intended for installation into a suitable enclosure.
The optical radiation output of the product with respect to explosion protection, according to Annex II clause 1.3.1 of the Directive
2014/34/EU is not covered in this certificate.
Temperature range:
The relation between ambient temperature and the assigned temperature class is as follows:
Ambient temperature range Temperature class
-40 °C to +75 °C
T4
Electrical data
Model Construction
Version
Electrical Rating Relay Output
Models IE-SW-
VL09-6TX-3SC
and IE-SW-VL09T-
6TX-3SC
Ver. A 12-48Vdc, Max. 1.1A, Class 2 24Vdc, 1A, Resistive
Ver. B
12/24/48, 0.56/0.26/0.13A, Class 2 or
12-48Vdc, 0.56-0.26A, Class 2 or
12-48Vdc, 0.56A max. , Class 2 or
12Vdc, 0.56A , Class 2 or
24Vdc, 0.26A , Class 2 or
48Vdc, 0.13A, Class 2.
24Vdc, 1A, Resistive
Routine tests:
No routine tests were considered necessary.
[16] Descriptive Documents
The scheduled drawings are listed in the report no. provided under item no. [ 8 ] on page 1 of this Type Examination Certificate.
[17] Special Conditions of Use:
The Ethernet Communication devices are to be mounted in a tool-accessible ATEX-Certified IP54 enclosure in accordance with
EN 60079-15, and used in an area of not more than pollution degree 2 as defined by EN 60664-1.
Provisions shall be made either in the equipment or external to the equipment to provide the transient protection device to be set
at a level not exceeding 140% of the peak rated voltage.
[18] Essential Health and Safety Requirements
The Essential Health and Safety Requirements (EHSRs) covered by the standards listed at item 9
Additional information
The trademark will be used as the company identifier on the marking label.