Approval/Certificate/Document of Conformity

[13]
Schedule
[14]
TYPE EXAMINATION CERTIFICATE No.
DEMKO 18 ATEX 2137X
Rev. 0
00-IC-F0060-1 – Issue 15.1
This certificate may only be reproduced in its entirety and without any change, schedule included.
Page 2 of 2
[15] Description of Product:
Models IE-SW-VL08MT-8TX, IE-SW-VL08MT-6TX-2ST, IE-SW-VL08MT-6TX-2SC and IE-SW-VL08MT-6TX-2SCS are DIN rail mounted
industrial Ethernet devices and Media Converters. They provide LAN capabilities in an industrial environment and are to be installed in a
suitable enclosure.
No.
of Ports
Model RJ 45 (10/100 Base T(x))
Ports
Fiber Ethernet – SC
Type
Fiber Ethernet – ST
Type
IE
-
-
VL08MT
-
8TX
8
-
-
IE
-
-
VL08MT
-
6TX
-
2SCS
6
2
-
IE
-
-
VL08MT
-
6TX
-
2SC
6
2
-
IE
-
-
VL08MT
-
6TX
-
2ST
6
-
2
For Models IE-SW-VL08MT-6TX-2ST, IE-SW-VL08MT-6TX-2SC and IE-SW-VL08MT-6TX-2SC , the optical radiation output of the product
with respect to explosion protection, according to Annex II clause 1.3.1 of the Directive 2014/34/EU is covered in this certificate.
For Model IE-SW-VL08MT-8TX , the optical radiation output of the product with respect to explosion protection, according to Annex II
clause 1.3.1 of the Directive 2014/34/EU is not covered in this certificate.
Temperature range:
The relation between ambient temperature and the assigned temperature class is as follows:
Ambient temperature range
Temperature class
-40
°
C to +75
°
C
T4
Electrical data
Model Electrical Rating Protection Method
IE-SW-VL08MT-8TX 12 Vdc, 0.61 A or 24Vdc, 0.3A or 48Vdc 0.16 A,
Relay Output 1 A @ 24 Vdc
nA nC
IE-SW-VL08MT-6TX-2ST,
IE-SW-VL08MT-6TX-2SC,
IE-SW-VL08MT-6TX-2SC
12 Vdc, 0.61 A or 24Vdc, 0.3A or 48Vdc 0.16 A
24 Vdc, Relay Output 1 A @ 24 Vdc nA nC op is
Routine tests:
No routine tests are necessary.
[16] Descriptive Documents
The scheduled drawings are listed in the report no. provided under item no. [ 8 ] on page 1 of this Type Examination Certificate.
[17] Special Conditions of Use:
Provisions shall be made to provide the transient protection to be set at a level not exceeding 140% of the peak rated voltage.
These devices shall be mounted in a suitable tool-accessible ATEX-Certified enclosure rated to at least IP54 as defined in EN 60529 and
Pollution Degree 2 as defined in EN 60664-1 and used within their rated electrical and environmental ratings.
[18] Essential Health and Safety Requirements
The Essential Health and Safety Requirements (EHSRs) covered by the standards listed at item 9.
Additional information
The trademark will be used as the company identifier on the marking label.