NOTE: Some operating systems will open the configuration file and log file directly
in the web page. In such cases, right click the Export button to save the file.
Upgrade Firmware
To import a new firmware file into the Weidmüller switch, click Browse to select the firmware file that
is saved on your computer. The upgrade procedure will proceed automatically after clicking Import.
Upload Configure Data
To import a configuration file into the Weidmüller switch, click Browse to select the configuration file
already saved on your computer. The upgrade procedure will proceed automatically after clicking
button Import.
3.1.9.3 System File Update by EBR-Module
You can use Weidmüller´s External Backup and Restore Module (can be ordered separately under
article no.: 1241430000) to save and load the Weidmüller switch’s configurations using the switch’s
RS-232 console port (RJ45 connector on top of the housing).
Auto load EBR-Module´s system configurations when system boots up
Setting
Description
Factory
Default
Enable
Enables Auto load system configurations from
EBR-Module when system boots up
Enable
Disable
Disables Auto load system configurations from
EBR-Module when system boots up
If enabled the configuration of a connected EBR-Module will be loaded and saved automatically into
the Switch when the device is booting.
Save the current configurations to the EBR-Module
To export the current configuration file of the Weidmüller switch, click on button Save to save it to the