Approval/Certificate/Document of Conformity
[13]
Schedule
[14] TYPE EXAMINATION CERTIFICATE No.
DEMKO 11 ATEX 150194X Rev. 3
00-IC-F0060-1 – Issue 13.2
This certificate may only be reproduced in its entirety and without any change, schedule included. Page 2 of 2
[15] Description of Product:
Models IE-SW-VL08-8GT, IE-SW-VL08T-8GT, IE-SW-VL08-6GT-2GS and IE-SW-VL08T-6GT-2GS are open type Ethernet switches with
communication interface and are intended for use in industrial automation applications. They are microcomputer-based and communicate
via interfaces through wire. These devices are open-type devices intended for installation in an ultimate enclosure The subject Models
consist of two circuit boards and utilize Non-Sparking ”nA” and the Sealed Device ”nC” protection methods.
Model Differences -
IE-SW-VL08-8GT,IE-SW-VL08T-8GT
IE-SW-VL08-6GT-2GS, IE-SW-VL08T-6GT-2GS
Ethernet RJ45
Eight provided
Eight provided
Fiber
N/A
Two provided
Model IE-SW-VL08-8GT is identical to Model IE-SW-VL08T-8GT except for model designation. Model IE-SW-VL08-6GT-2GS is identical to
Model IE-SW-VL08T-6GT-2GS except for model designation. The difference between the Models is software related.
Models IE-SW-VL08-6GT-2GS and IE-SW-VL08T-6GT-2GS provide two fiber.
The optical radiation output of the productwith respect to explosion protection, according to Annex II clause 1.3.1 of the Directive
2014/34/EU is not covered in this certificate.
Temperature range:
The relation between ambient temperature and the assigned temperature class is as follows:
Ambient temperature range
Temperature class
-40 °C to +75 °C
-10 °C to +60°C (Alternate circuit board without suffix–T)
T4
Electrical data
Model Nos.
Rated Supply Voltage and Current
Relay Contact Rating
IE-SW-VL08-8GT,
IE-SW-VL08T-8GT
12-48 V dc, Class 2, Maximum 0.8 A
24 V dc, 1 A, resistive load
IE-SW-VL08-6GT-2GS,
IE-SW-VL08T-6GT-2GS
12-48 V dc, Class 2, Maximum 0.9 A
Routine tests:
No routine tests necessary.
[16] Descriptive Documents
The scheduled drawings are listed in the report no. provided under item no. [ 8 ] on page 1 of this Type Examination Certificate.
[17] Special Conditions of Use:
• Subject devices are to be installed in an ATEX Certified enclosure rated not less than IP54 and accessible only by the use of a tool.
• Subject devices are for use in an area of not more than pollution degree 2 in accordance with EN 60664-1.
• Transient protection shall be provided to limit the peak rated voltage to maximum 140% of peak rated voltage
• When end users are providing optical SFP communication modules, this must be limited to laser Class 1 only.
[18] Essential Health and Safety Requirements
The Essential Health and Safety Requirements (EHSRs) covered by the standards listed at item 9
Additional information
The trademark will be used as the company identifier on the marking label.