User Documentation
User Manual Managed Switches 
24 
Default Gateway 
Setting 
Description 
Factory 
Default 
IP address for the 
gateway   
The IP address of the router that connects the LAN to 
an outside network. 
None 
DNS IP Address 
Setting 
Description 
Factory 
Default 
1st DNS Server’s 
IP address 
The IP address of the DNS Server used by your 
network. After entering the DNS Server's IP address, 
you can input the Weidmüller Switch's URL (e.g., 
www.VL08M.company.com) in your browser's address 
field, instead of entering the 
IP address. 
None 
2nd DNS Server’s 
IP address 
The IP address of the secondary DNS Server used by 
your network. The Switch will use the 2nd DNS Server 
if the 1st DNS Server fails to connect. 
None 
DHCP Retry Periods 
Setting 
Description 
Factory 
Default 
1 to 30 
Users can configure the DHCP retry period manually 
1 
DHCP Retry Times 
Setting 
Description 
Factory 
Default 
0 to 65535 
Users can configure the times of DHCP retry manually 
0 
IP6 Settings 
IPv6 setting includes two distinct address types—Link-Local Unicast address and Global Unicast 
address. A Link-Local address makes the switch accessible over IPv6 for all devices attached to the 
same local subnet. To connect to a larger network with multiple segments, the switch must be 
configured with a Global Unicast address. 
Global Unicast Address Prefix (Prefix Length: 64 bits) Default Gateway 
Setting 
Description 
Factory 
Default 
Global 
Unicast 
Address 
Prefix 
The prefix value must be formatted according to RFC 
2373 "IPv6 Addressing Architecture," using 8 
colon-separated 16-bit hexadecimal values. One 
double colon may be used in the address to indicate 
the appropriate number of zeros required to fill the 
undefined fields. 
None 