User Documentation
- 14 -
Optical Fiber-1000BaseSX/LX/LHX
SX
LX
LHX
Wavelength
850 nm
1310 nm
1310 nm
Max. Tx
-4 dBm
-3 dBm
1 dBm
Min. Tx
-9.5 dBm
-9.5 dBm
-4 dBm
Rx Sensitivity
-18 dBm
-20 dBm
-24 dBm
Link Budget
8.5 dB
10.5 dB
20 dB
Typical Distance
550m (a)
275m (b)
1100m (c)
550m (d)
10km (e)
40km (e)
Saturation
0 dBm
-3 dBm
-3 dBm
a. [50/125 μm, 400 MHz*km] cable b. [62.5/125 μm, 200 MHz*km] cable
c. [50/125 μm, 800 MHz*km] cable d. [62.5/125 μm, 500 MHz*km] cable
e. [9/125 μm, 3.5 PS/(nm*km)] cable
Power
Input Voltage
24 VDC (12 to 45 VDC), redundant inputs
Input Current (@24V)
0.51A: IE-SW-PL18M-2GC-16TX
0.61A: IE-SW-PL18M-2GC14TX2SC/2ST/2SCS
Connection
Two removable 6-pin terminal blocks
Overload Current Protect.
Present
Reverse Polarity Protection
Present
Mechanical
Casing
IP30 protection, metal case
Dimensions
95 135 140 mm (W H D)
Weight
1.63 kg
Installation
DIN-Rail, Wall Mounting
Environment
Operating Temperature
0 to 60°C (32 to 140°F)
-40 to 75°C (-40 to 167°F) for -T models
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5% to 95% (non-condensing)
Regulatory Approvals
Safety
UL60950-1, UL 508
CSA C22.2 No. 60950-1, EN60950-1
Hazardous Location
UL/cUL Class I, Division 2, Groups A, B, C, and
D. ATEX Zone 2: Ex nA nC IIC T4 Gc
EMI
FCC Part 15, CISPR (EN55022) class A
EMS
EN61000-4-2 (ESD), Level 2
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 2
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
EN61000-4-8
EN61000-4-11
EN61000-4-12