User Documentation
User Manual Managed Switches 
67 
NOTE: When using the Dual-Ring architecture, users must configure settings for both Ring 1 and 
Ring 2. In this case, the status of both rings will appear under “Current Status.” 
Explanation of “Current Status” Items 
Now Active 
It shows which communication protocol is in use: Turbo Ring, Turbo Ring V2, Turbo Chain, RSTP, 
or none. 
Ring 1/2—Status 
It shows Healthy if the ring is operating normally, and shows Break if the ring’s backup link is active. 
Ring 1/2—Master/Slave 
It indicates whether this switch is the Master (or not) of the Turbo Ring. This field appears only when 
Turbo Ring or Turbo Ring V2 modes are selected. 
NOTE: The user does not need to set the master to use Turbo Ring. If master is not set, the Turbo 
Ring protocol will assign master status to one of the Switch units in the ring. The master is only used 
to determine which segment serves as the backup path. 
Ring 1/2—1st/2nd Ring Port Status 
The “Ports Status” indicators show Forwarding for normal transmission, Blocking if this port is 
connected to a backup path and the path is blocked, and Link down if there is no connection. 
Coupling—Mode 
It indicates either None, Dual Homing or Ring Coupling. 
Coupling—Coupling Port status 
It indicates either Primary Port status or Backup Port status. 