User Documentation
User Manual Managed Switches 
169 
5 
Get 
Port Type Name   
SHORT_ 
STR ING 
String which names the port 
type. The maximum number 
of characters in the string is 
64. 
6 
Get/Set 
Port Description   
SHORT_ 
STR ING 
String which describes the 
port. The maximum number of 
characters in the string is 64. 
7 
Get 
Node Address   
Padded   
EPATH 
Node number of this device on 
port. The range within this 
data type is restricted to a Port 
Segment. 
9 
Get 
Port Key 
Padded   
EPATH 
Electronic key of 
network/chassis this port is 
attached to. This attribute 
shall be limited to format 4 of 
the Logical Electronic Key 
segment. 
Common Service List 
Service 
Code 
Implementation 
Service Name 
Description 
Class 
Instance 
0x0E
 
 
Get_Attribute_Single
Used to read an object instance 
attribute
0x10
 
Set_Attribute_Single
Used to modify an object instance 
attribute
Weidmüller Networking Object 
The Weidmüller Networking object includes system information and status. 
It can also be used to do the device diagnostic & configuration through explicit messaging. The class 
code is 0x404. 
Class Attribute List 
Attr ID   
Access Rule   
Name   
Data Type   
Description   
1   
Get 
Revision   
UINT (16)   
Revision of this object   
Instance Attribute List 
Attr ID   
Access Rule   
Name   
Data Type   
Description   
1 
Get 
Firmware 
Version 
UDINT (32)   
Switch firmware version 
2 
Get 
System Fault 
Status 
UDINT (32)   
Switch fault status   
Bit 0: Reserved (0 = Ok, 1 = Fail) 
Bit 1: Reserved (0 = Ok, 1 = Fail) 
Bit 2: Port utilization alarm (0 = No 
alarm , 1 = alarm) 
Bit 3: Port link up (0 = No alarm, 1 = 