User Documentation
User Manual Managed Switches 
42 
(Max. 32 users) 
Database as the authentication database. 
Radius 
Select this option to set an external RADIUS server as 
the authentication database. The authentication 
mechanism is EAP-MD5. 
Local 
Radius, Local 
Select this option to make using an external RADIUS 
server as the authentication database the first priority. 
The authentication mechanism is EAP-MD5 The first 
priority is to set the Local User Database as the 
authentication database. 
Local 
Radius Server 
Setting 
Description 
Factory 
Default 
IP address or 
domain name 
The IP address or domain name of the RADIUS server 
local host 
Server Port 
Setting 
Description 
Factory 
Default 
Numerical 
The UDP port of the RADIUS server 
1812 
Shared Key 
Setting 
Description 
Factory 
Default 
alphanumeric 
(Max. 40 
characters) 
A key to be shared between the external RADIUS 
server and the Weidmüller switch. Both ends must be 
configured to use the same key. 
None 
Re-Auth 
Setting 
Description 
Factory 
Default 
Enable/Disable 
Select enable to require re-authentication of the client 
after a preset time period of no activity has elapsed. 
Disable 
Re-Auth Period 
Setting 
Description 
Factory 
Default 
Numerical 
(60 to 65535 sec) 
Specify how frequently the end stations need to 
reenter usernames and passwords in order to stay 
connected. 
3600 
802.1X 
Setting 
Description 
Factory 
Default 
Enable/Disable 
Checkmark the checkbox under the 802.1X column to 
Disable 