User Documentation
User Manual Managed Switches 
149 
To monitor Port data, follow the same steps, drag Port data in the side bar and drop it onto slot 2.   
Then right click on slot 2 and select Monitor/Modify. 
You will see a monitoring window. Please refer to the 
PROFINET Cyclic I/O data table to see the meaning 
of each bit.   
For example, address 1.3 is set to Bit 1. It represents 
the connection status of Port 4 of the switch. Bit 1 
means that a connection is present at Port 4 and 
Green will be displayed in the section Status value. 
Module Information 
Weidmüller switches support SIMATIC STEP 7 Ethernet traffic information monitoring and 
PROFINET alarms. These attributes can be monitored in module information dialog. Following are 
the steps of operation. 
1. Select Weidmüller switch icon in the HW config. 
2. Click menu bar PLC > Module Information 










