User Documentation
User Manual Managed Switches 
113 
Power Transition (On -> 
Off) 
Weidmüller switch is powered down 
Power Transition (Off -> 
On) 
Weidmüller switch is powered up 
DI1 (OnOff) 
Digital Input 1 is triggered by on to off transition 
DI1 (OffOn) 
Digital Input 1 is triggered by off to on transition 
DI2 (OnOff) 
Digital Input 2 is triggered by on to off transition 
DI2 (OffOn) 
Digital Input 2 is triggered by off to on transition 
Turbo Ring Break 
The Turbo Ring is broken. Only the MASTER switch of Turbo 
Ring will output warning relay. 
Port Events 
Warning e-mail is sent when… 
Link-ON 
The port is connected to another device. 
Link-OFF 
The port is disconnected (e.g., the cable is pulled out, or the 
opposing device shuts down). 
Traffic-Overload 
The port’s traffic surpasses the Traffic-Threshold for that port 
(provided this item is Enabled). 
Traffic-Threshold (%) 
(0 to 100 %) 
Enter a nonzero number if the port’s Traffic-Overload item is 
Enabled. 
Traffic-Duration (sec.) 
(1 to 300 sec.) 
A Traffic-Overload warning is sent every Traffic-Duration seconds 
if the average Traffic-Threshold is surpassed during that time 
period. 
NOTE: The Traffic-Overload, Traffic-Threshold (%), and Traffic-Duration (sec) Port 
Event items are related. If you Enable the Traffic-Overload event, then be sure to enter a 
non-zero Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 
seconds. 
Override relay alarm settings 
Select this option to override the relay warning setting temporarily. Releasing the relay output will 
allow administrators to fix any problems with the warning condition. 
Warning List 
The Current Warning List can be used to see if any relay alarms have been issued. 