Mechanical 
Casing 
IP30 protection, metal case 
Dimensions   
95  135  140 mm (W  H  D) 
Weight   
1.586 kg 
Installation   
DIN-Rail, Wall Mounting 
Environment 
Operating Temperature 
0 to 60°C (32 to 140°F) 
-40 to 75°C (-40 to 167°F) for -T models 
Storage Temperature 
-40 to 85°C (-40 to 185°F) 
Ambient Relative Humidity 
5% to 95% (non-condensing) 
Regulatory Approvals 
Safety 
UL 508, UL60950-1 
CSA C22.2 No. 60950-1, EN60950-1 
Hazardous Location 
UL/cUL Class I, Division 2, Groups A, B, C, and 
D. ATEX, Zone 2: Ex nA nC IIC T4 Gc 
EMI 
FCC Part 15, CISPR (EN55022) class A 
EMS 
EN61000-4-2 (ESD), Level 2 
EN61000-4-3 (RS), Level 3 
EN61000-4-4 (EFT), Level 2 
EN61000-4-5 (Surge), Level 3 
EN61000-4-6 (CS), Level 3 
EN61000-4-8 
EN61000-4-11 
EN61000-4-12 
Shock 
IEC60068-2-27 
Freefall 
IEC60068-2-32 
Vibration 
IEC60068-2-6 
WARRANTY 
5 years 
Weidmüller gives a 5 year warranty on this product in accordance with the 
warranty terms as described in the general conditions of sale of the Weidmüller 
company which has sold the products to you. Weidmüller warrants to you that 
such products the defects of which have already existed at the time when the 
risk passed will be repaired by Weidmüller free of charge or that Weidmüller 
will provide a new, functionally equivalent product to replace the defective one. 
Safe where expressly described otherwise in writing in this catalogue/product 
description, Weidmüller gives no warranty or guarantee as to the 
interoperability in specific systems or as to the fitness for any particular 
purpose. To the extent permitted by law, any claims for damages and 
reimbursement of expenses, based on whatever legal reason, including contract 
or tort, shall be excluded. Where not expressly stated otherwise in this warranty, 
the general conditions of purchase and the expressive liability commitments 
therein of the respective Weidmüller company which has sold the products to 
you shall be applicable. 