User Documentation
User Manual Managed Switches 
148 
connected 
Monitor PROFINET I/O Cyclic Data 
Weidmüller switches provide PROFINET I/O cyclic data 
for real-time monitoring. In side bar you can see Device 
data and Port data. 
To monitor Device data, use Drag & Drop to pull the Device data onto slot 1. Right-click on slot 1, 
then select Monitor/Modify. 
Use Monitor to check the input data value. In this 
dialog, select Monitor and then, you can see the 
status value of each address. Please refer to the 
PROFINET Cyclic I/O data table to see the 
meaning of each bit.   
For example, address 0.2 is set to Bit 1. It represents 
Power 2 status of the switch. 1 means Power 2 is 
present and Green will be displayed in the section 
Status value. 
Refer to the PROFINET Cyclic I/O data table at the beginning of this chapter for the meanings of 
each address. 