Electrical data 
Model Nos.  
Rated Supply Voltage and Current  
IE-SW-BL05-5TX,  
IE-SW-BL05T-5TX,  
IE-SW-BL05-4TX-1SCS,  
IE-SW-BL05T-4TX-1SCS,  
IE-SW-BL05-4TX-1ST,  
IE-SW-BL05T-4TX-1ST ,  
IE-SW-BL05-4TX-1SC ,  
IE-SW-BL05T-4TX-1SC  
12/24/48 V dc, Maximum 0.25 A, Class 2, or  
18-30 V ac, 50/60 Hz, Maximum 0.25 A, Class 2  
IE-SW-BL08-8TX,  
IE-SW-BL08T-8TX  
12/24/48 V dc, Maximum 0.35 A, Class 2, or  
18-30 V ac, 50/60 Hz, Maximum 0.35 A, Class 2  
IE-SW-BL08-6TX-2SC,  
IE-SW-BL08T-6TX-2SC,  
IE-SW-BL08-6TX-2ST,  
IE-SW-BL08T-6TX-2ST,  
IE-SW-BL08-6TX-2SCS  
IE-SW-BL08T-6TX-2SCS  
12/24/48 V dc, Maximum 0.65 A, Class 2, or  
18-30 V ac, 50/60 Hz, Maximum 0.65 A, Class 2  
IE-SW-BL08-7TX-1SCS,  
IE-SW-BL08T-7TX-1SCS,  
IE-SW-BL08-7TX-1SC,  
IE-SW-BL08-7TX-1ST,  
IE-SW-BL08T-7TX-1SC,  
IE-SW-BL08T-7TX-1ST  
12/24/48 V dc, Maximum 0.5 A, Class 2, or  
18-30 V ac, 50/60 Hz, Maximum 0.5 A, Class 2  
For Alternate construction 
of Model IE-SW-BL08(X)-7TX-1SC, IE-SW-
BL08(X)-7TX-1ST, IE-SW-BL08(X)-6TX-2SC, 
IE-SW-BL08(X)-6TX-2ST, IE-SW-BL08(X)-
7TX-1SCS, IE-SW-BL08(X)-6TX-2SCS 
12/24/48 VDC, 0.3/0.15/0.08A, Class 2 or 
12-48 VDC, 0.3-0.08A, Class 2 or 
12 VDC, 0.3A, Class 2 or 
24 VDC, 0.15A, Class 2 or 
48 VDC, 0.08A, Class 2 or 
12-48 VDC, 0.3A max., Class 2 
Routine tests: 
No routine tests were considered necessary. 
 [16]  Descriptive Documents 
The scheduled drawings are listed in the report no. provided under item no. [ 8 ] on page 1 of this Type Examination Certificate. 
 [17]  Special Conditions of Use: 
•  Devices are to be installed in an ATEX certified IP54 enclosure accessible only with use of a tool and used in an area of not more 
than pollution degree 2 as defined by EN 60664-1. 
•  Provisions shall be made to provide the transient protection device to be set at a level not exceeding 140% of the peak rated voltage. 
 [18]  Essential Health and Safety Requirements 
The Essential Health and Safety Requirements (EHSRs) covered by the standards listed at item 9. 
Additional information 
The trademark  will be used as the company identifier on the marking label. 