Approval/Certificate/Document of Conformity
[13] Schedule
[14] TYPE EXAMINATION CERTIFICATE No.
DEMKO 16 ATEX 1727X Rev. 0
00-IC-F0060 – Issue 12.0 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 2 of 2
[15] Description of Product:
Models IE-SW-BL05-4GT-1GS and IE-SW-BL05T-4GT-1GS are open type, programmable controllers with communication interface and
intended for use in industrial applications. They are microcomputer-based and communicate via interfaces through wire. These subject
devices are intended for installation into an ultimate enclosure that uses a tool removable cover/door.
The optical radiation output of the apparatus with respect to explosion protection, according to Annex II clause 1.3.1 of the Directive
2014/34/EU is not covered in this certificate.
Models IE-SW-BL05-4GT-1GS and IE-SW-BL05T-4GT-1GS have same constructions except for ambient temperature range.
Temperature range:
The relation between ambient temperature and the assigned temperature class is as follows:
Model
Ambient temperature range
Temperature class
IE-SW-BL05-4GT-1GS
-10 C to +60 C
T4
IE-SW-BL05T-4GT-1GS
-40 C to +75 C
T4
Electrical data:
Input: 12-48 V dc, 380 mA, Class 2
Relay Output: 24 V dc, 1 A, Resistance, Class 2.
Mounting instructions:
Devices can be either DIN-rail or wall mounted.
Routine tests:
No Routine Tests are necessary.
[16] Descriptive Documents
The scheduled drawings are listed in the report no. provided under item no. [ 8 ] on page 1 of this Type Examination Certificate.
[17] Special Conditions of Use:
The equipment shall be installed in an enclosure that provides a degree of protection not less than IP 54 in accordance with EN
60079-15 and accessible only by the use of a tool.
Devices are for use in an area of not more than pollution degree 2 in accordance with EN 60664-1.
When end users are providing Optical SFP Communications modules, these must be limited to Laser Class 1 only.
[18] Essential Health and Safety Requirements
Met by compliance with the standards EN 60079-0:2012+A11:2013, EN 60079-15:2010.
The trademark will be used as the company identifier on the marking label.