Approval/Certificate/Document of Conformity
[13] Schedule
[14] TYPE EXAMINATION CERTIFICATE No.
DEMKO 13 ATEX 1207259X Rev. 1
00-IC-F0060-1 – Issue 13.2 This certificate may only be reproduced in its entirety and without any change, schedule included. Page 2 of 2
[15] Description of Product:
The subject models are DIN rail mounted industrial application Ethernet communication devices. They are intended for Industrial
Applications, pollution degree 2 environments. They are microcomputer-based and communicate via interfaces through wire.
Subject models are of the open type and are intended for installation into a suitable enclosure.
Programmable Controllers, Series IE, maybe followed by -CS or -CST, followed by -2TX, may be followed by -1RS232/485 or -2RS232/485
The optical radiation output of the productwith respect to explosion protection, according to Annex II clause 1.3.1 of the Directive
2014/34/EU is covered in this certificate based on Exception 1) to the scope of EN 60079-28:2015.
Model Difference – As outlined below.
IE-CS-2TX-1RS232/485
IE-CST-2TX-1RS232/485
IE-CS-2TX-2RS232/485
IE-CST-2TX-2RS232/485
Ethernet RJ45
Two provided
Two provided
RS232
One provided
Two provided
Signal Channel
Five Channels
N/A
Temperature range:
The relation between ambient temperature and the assigned temperature class is as follows:
Ambient temperature range
Temperature class
-40 C to +75 C
T3
Electrical data
Model
Rating
Series IE, maybe followed by -CS or -CST, followed by -
2TX, may be followed by -1RS232/485 or -2RS232/485
Input: 12-48 V dc, max. 500 mA, Class 2
Relay Output: 24 V dc, 1 A, Resistive Load
Routine tests:
None
[16] Descriptive Documents
The scheduled drawings are listed in the report no. provided under item no. [ 8 ] on page 1 of this Type Examination Certificate.
[17] Special Conditions of Use:
The Ethernet Communication Devices are to be mounted in a tool-accessible ATEX certified IP54 enclosure and used in an area of
not more than pollution degree 2 as defined by EN 60664-1.
Provisions shall be made to provide the transient protection device to be set at a level not exceeding 140% of the peak rated
voltage.
[18] Essential Health and Safety Requirements
The Essential Health and Safety Requirements (EHSRs) covered by the standards listed at item 9.
Additional information
The trademark will be used as the company identifier on the marking label.