User Documentation
IE-CS(T)-2TX-xRS232/485  Web Console Configuration 
5-33
SNMP Trap Server 
SNMP trap server IP or domain name 
Setting  Factory Default  Necessity 
IP address or Domain 
Name 
None Optional 
Event Type 
Cold start 
This refers to starting the system from power off (contrast this with warm start). When performing a cold start, 
the IE-CS(T)-2TX-xRS232/485 will automatically issue an Auto warning message by e-mail, or send an SNMP 
trap after booting up. 
Warm start 
This refers to restarting the computer without turning the power off. When performing a warm start, the 
IE-CS(T)-2TX-xRS232/485 will automatically send an e-mail, or send an SNMP trap after rebooting. 
Authentication failure 
The user inputs a wrong password from the Console or Administrator. When authentication failure occurs, the 
IE-CS(T)-2TX-xRS232/485 will immediately send an e-mail or send an SNMP trap. 
IP address changed 
The user has changed the IE-CS(T)-2TX-xRS232/485’s IP address. When the IP address changes, the 
IE-CS(T)-2TX-xRS232/485 will send an e-mail with the new IP address before the IE-CS(T)-2TX-xRS232/485 
reboots. If the IE-CS(T)-2TX-xRS232/485 is unable to send an e-mail message to the mail server within 15 
seconds, the IE-CS(T)-2TX-xRS232/485 will reboot anyway, and abort the e-mail auto warning. 
Password changed 
The user has changed the IE-CS(T)-2TX-xRS232/485’s password. When the password changes, the 
IE-CS(T)-2TX-xRS232/485 will send an e-mail with the password changed notice before the 
IE-CS(T)-2TX-xRS232/485. If the the IE-CS(T)-2TX-xRS232/485 is unable to send an e-mail message to the 
mail server within 15 seconds, the IE-CS(T)-2TX-xRS232/485 will reboot anyway, and abort the e-mail auto 
warning. 










