User Documentation
IE-CS(T)-2TX-xRS232/485  Web Console Configuration 
5-12
TCP alive check time 
Setting  Factory Default  Necessity 
0 to 99 min  7 min  Optional 
0 min: TCP connection is not closed due to an idle TCP connection. 
1 to 99 min: the IE-CS(T)-2TX-xRS232/485 will automatically close the TCP connection if there is no TCP 
activity during this given time. After the connection has closed, the IE-CS(T)-2TX-xRS232/485 will start 
“listening” for another Real COM driver connection from another host. 
Max connection 
Setting  Factory Default  Necessity 
1, 2, 3, 4, 5, 6, 7, 8  1  Required 
Max connection is usually used when the user needs to receive data from different hosts simultaneously. The 
factory default is 1, this means that only one specific host can access this IE-CS(T)-2TX-xRS232/485, and the 
Real COM driver on that host will have full control over the port. 
Max Connection 1:
Only a single host’s Real COM driver can access the specific IE-CS(T)-2TX-xRS232/485 serial port. 
Max Connection 2 to 8:
Allows two to eight host’s Real COM drivers to access the specific IE-CS(T)-2TX-xRS232/485 serial port at the 
same time. When multiple hosts’ Real COM drivers access the serial port at the same time, the COM driver only 
provides pure data tunneling without control ability. This means that the serial port will use the parameter of 
the firmware’s settings and not those of your application program (AP). 
Application software that is based on the COM driver will receive a driver response of “success” when the 
software uses any of the Win32 API functions. The firmware will only send the data back to the driver on the 
host. 
Data will be sent first-in-first-out when the data is received by the IE-CS(T)-2TX-xRS232/485 from the 
Ethernet interface. 
ATTENTION 
When "Max connection" is set greater than 1, this means that the IE-CS(T)-2TX-xRS232/485 will be using a
“
multi connection application” (i.e., up to eight hosts are allowed access to the port at the same time). When
using a multi connection application, the IE-CS(T)-2TX-xRS232/485 will use the serial communication 
parameters set in the console. All of the hosts connected to that port must use the same serial settings. If one
of the hosts opens the COM port with parameters that are different from the IE-CS(T)-2TX-xRS232/485’s 
console setting, data communication may not transmit properly. 
Ignore jammed IP 
Setting  Factory Default   Necessity 
No or Yes    No    Optional 
If you select “No” when Max connections is > 1 and the serial device is transmitting data, in the event one of 
the connected hosts is not responding, the second group of data will not be sent until all the data from the first 
group has been successfully transmitted. If you select “Yes” for “Ignore jammed IP,” hosts that are not 
responding will be ignored, but the data will still be transmitted to all the other hosts. 