To modify the serial settings for a specific port, click Port X (X=1 or 2) under Serial Settings. 
Port alias 
Setting  Factory Default  Necessity 
1 to 15 characters 
(E.g., PLC-No.1) 
None Optional 
“Port alias” is included to allow easy identification of the serial devices that are connected to the 
IE-CS(T)-2TX-xRS232/485’s serial ports. 
Serial Parameters 
ATTENTION 
Check the serial communication parameters in your Serial Device’s user’s manual. You should set up the 
IE-CS(T)-2TX-xRS232/485’s serial parameters with the same communication parameters being used by your
serial devices. 
Baudrate 
Setting  Factory Default  Necessity 
50 bps to 921.6 Kbps  115.2 Kbps  Required 
Data bits 
Setting  Factory Default  Necessity 
5, 6, 7, 8  8  Required 
When a user sets the Data bits to 5 bits, the Stop bits setting will automatically change to 1.5 bits. 
Stop bits 
Setting  Factory Default  Necessity 
1, 1.5, 2  1  Required 
Stop bits will be set to 1.5 when the Data bits is set to 5 bits. 
Parity 
Setting  Factory Default  Necessity 
None, Even, Odd, 
Space, Mark 
None Required 