User Documentation
Operating the machine
2549630000/00/09.201736
6.4 Resetting the day's piece quantity
► Select Menu 1, if it is not already displayed.
1. Production menu
Ready Device is ready for operation
DPQ 5 Day's piece quantity: Quantity of
processed pieces since the last
reset.
Step: 1/0
C E
► To reset the day's piece quantity, hold down C for at
least 5 seconds.
The day's piece quantity is reset to zero.
6.5 Changing operating mode
► Select Menu 3.
The current operating mode is displayed.
3. Stripping menu
Stripping: 0 0 = Stripping and crimping
1 = Only stripping
C E
► To switch operating mode, press E.
The selected operating mode is immediately active.
► To reach the production menu again, C, or choose
another menu with the arrow keys.
6.6 Displaying counters and processing
times
► Select Menu 4.
4. Operating data
menu
Tcounter: 400002 Total counter: Number of com-
pleted work cycles
Pr.Time:
1.496s
Processing time: Work cycle
duration (stripping and crimping)
Service: – 1 Prex sign and service counter
C E
The total counter counts the work cycles during the entire
lifetime of the machine. The service interval of the machine
is 400,000 work cycles. The service counter counts down
instead of up; starting at 400,000. Once 400,000 work
cycles have been completed, the service counter stands
at 0. When the machine is next started, the service noti-
cation is displayed (see section 6.9). The service counter
counts up again. The negative prex sign indicates that a
counting cycle has been completed. The service technician
sets the service counter to 400,000.