3.1 Technical data
Crimpx R Crimpx RS
Drive Electropneumatic
Supply voltage 100–240 V AC; 50/60 Hz
Power consumption 110 VA
Fuse (mains lter module) 2xT2AH250V
Protection type IP 20
Protection class I / protective earth conductor
Operating pressure 5.5 bar
Air consumption Approx.0.9nl/stop
Cable insertion length 35 mm (1.37") 27 mm (1.06") + crimp length
Crimping length 8 mm (0.31") 8 / 10 mm (0.31" / 0.39")
Wire-end ferrule 0.5 to 2.5 mm
2
(AWG 20 to 14)
Crimp form Trapezium
Cycle time 1.5 s
Ambient temperature
Operation +5 °C to 40 °C
Storage / transport -25 °C to +55 °C (brief +70 °C)
Internal temperature in operation Max.45°C
Max. operating height 2000 m above seal level
Humidity 50% at +40 °C (without condensation), 90% at +20 °C (without condensation)
Contamination level 2
Continuous sound pressure level < 70 dB (A)
Dimensions (WxDxH) 390x330x460mm(15.35"x12.99"x18.11")
Colour RAL 2000
Weight 23 kg (50.71 lbs)
3.2 Type plate
1
2
3
4
5
Figure 3.3 Type plate on machine rear
1 Manufacturer
2 Model, type description
3 Serial number
4 Technical specifications
5 Year of construction