User Documentation

472518100000/03/06.2017
If a fault cannot be resolved by means of the ac-
tions described here, please refer to Weidmüller
Service.
8.1 Fault table
Fault Possible cause Recommended action
Machine cannot be switched
on.
No power supply Check the power cable and the mains connec-
tions.
Check fuses.
Cannot start if wire is in-
serted.
Start sensor (S1) is blocked by strip-
ping leftovers.
Open the front plate.
Swing the tool unit to the right.
Pull the stranded wire xing unit forwards.
Remove the leftovers from the stripping unit.
Bring all components back into their original
positions.
Wire has been inserted incorrectly. Insert the wire straight.
The wire is only stripped and
not crimped.
"Only stripping" operating mode is set. Change the operating mode to "Standard"
(setting "0" in Menu 3).
Settings on the machine do not match
the ferrule used.
Check whether the settings for the ferrule
cross section and crimp length (only for LS
models) match the used ferrule.
No wire-end ferrules in the vibrating
conveyor bowl.
Fill the vibrating conveyor bowl with wire-end
ferrules.
Increased scrap Waste container is full Empty the waste container (see section 7.4).
Stripping blades damaged or incor-
rectly installed
Check the seating of the stripping blades (see
section 7.8).
Correct the seating of the stripping blades or
replace them (see section 8.3).
Stripping leftovers between tool unit
and right stop
Remove the stripping leftovers.
A second ferrule is located in the fer-
rule-holding unit
Remove the ferrule.
8.2 Wear parts
Product Order no.
Titanium stripping blades 1283530000
8 Troubleshooting