User Documentation
472518100000/03/06.2017
If a fault cannot be resolved by means of the ac-
tions described here, please refer to Weidmüller
Service.
8.1 Fault table
Fault Possible cause Recommended action
Machine cannot be switched
on.
No power supply ► Check the power cable and the mains connec-
tions.
► Check fuses.
Cannot start if wire is in-
serted.
Start sensor (S1) is blocked by strip-
ping leftovers.
► Open the front plate.
► Swing the tool unit to the right.
► Pull the stranded wire xing unit forwards.
► Remove the leftovers from the stripping unit.
► Bring all components back into their original
positions.
Wire has been inserted incorrectly. ► Insert the wire straight.
The wire is only stripped and
not crimped.
"Only stripping" operating mode is set. ► Change the operating mode to "Standard"
(setting "0" in Menu 3).
Settings on the machine do not match
the ferrule used.
► Check whether the settings for the ferrule
cross section and crimp length (only for LS
models) match the used ferrule.
No wire-end ferrules in the vibrating
conveyor bowl.
► Fill the vibrating conveyor bowl with wire-end
ferrules.
Increased scrap Waste container is full ► Empty the waste container (see section 7.4).
Stripping blades damaged or incor-
rectly installed
► Check the seating of the stripping blades (see
section 7.8).
► Correct the seating of the stripping blades or
replace them (see section 8.3).
Stripping leftovers between tool unit
and right stop
► Remove the stripping leftovers.
A second ferrule is located in the fer-
rule-holding unit
► Remove the ferrule.
8.2 Wear parts
Product Order no.
Titanium stripping blades 1283530000