User Documentation
Cleaning and maintaining the machine
2518100000/03/06.201746
7.12 Servicing the compressed air mainte-
nance unit
CAUTION
Risk of injury posed by electrical volt-
age!
► Make sure that the machine is switched o
and the mains plug has been pulled.
CAUTION
Risk of injury posed by compressed air
hoses swinging around!
► Make sure that the compressed air hose
is disconnected from the compressed air
source.
1
2
3
Figure 7.11 Compressed air maintenance unit
As required
► To drain the condensate press the drain plug (1) up-
wards.
► To change the lter, unscrew the condensate tank (2)
and screw o the lter (3).
► Insert a new lter and screw the condensate tank back
on tightly.