User Documentation
Cleaning and maintaining the machine
2518100000/03/06.201744
► Press the tool unit backwards and swing it to the right.
1
L, LS LZ
2
1
2
Figure 7.5 Stripping unit
► Clean the area around the hole (1) with a brush.
► If necessary, use a soft cloth and some spirit.
► Check the blade (2). If necessary, replace the blades
(see section 8.3).
7.9 Servicing the crimping tool
To reach the crimping tool, you must dismantle the strand-
ed wire xing unit.
► Ensure that the stranded wire xing unit is located in the
front position (gure 7.4, B).
► Remove the bottom right screw of the stranded wire x-
ing unit (gure 7.4, 4).
► Pull out the stranded wire xing unit carefully, forwards.
For Crimpx L: Ensure that the spacer ring stays on the
axis.
► Tilt the stranded wire xing unit to the side and place it
down carefully.
Figure 7.6 Detached stranded wire fixing unit
Weekly (only L PZ3 and LS PZ3):
Figure 7.7 Removing PZ3 crimp dies
► Remove the xing screw of each crimp die (2.5 mm Al-
len key).
► Pull the crimp dies up and out.