User Documentation

332518100000/03/06.2017
4 Transporting and setting up the machine
4.1 Installation location
The installation location must meet the following require-
ments:
Stable foundation with straight, even surface (for ma-
chine weight, see section 3.1).
Keep 30 cm work area free on both sides and in front of
the machine.
Electricity and compressed air ports easily accessible
close by.
Optimum operating pressure is 5.5 bar
(± 0.5 bar). When operating pressure is less than
5 bar, you will not achieve satisfactory crimping
results. Operating pressures greater than 6 bar
will lead to increased wear on the machine.
4.2 Transporting the machine
Always wear work shoes with foot protection
when transporting the machine.
Empty the waste container prior to each transport.
Note the weight of the machine (see section 3.1). Use a
transport aid if necessary.
To move the machine, always use the side carry han-
dles.
To prepare the machine for shipping (e.g. in the event of
servicing), use the transport packaging.
4.3 Unpacking the delivery
Check the delivery for completeness (for scope of deliv-
ery, see below).
Store away the transport packaging.
Ensure that the operating instructions are accessible to
the user at all times.
4.4 Scope of delivery
Stripping and crimping machine with oscillating conveyor
bowl
1 additional vibrating conveyor bowl
Mains connection cable (10 A, 250 V)
Compressed air hose
2.5 mm Allen key (LS: 2.5 mm and 5 mm)
Operating Instructions
4.5 Establishing connections
Set up the machine in the intended location.
3
1
4
2
Figure 4.1 Establishing connections
First switch on the compressed air hose on the com-
pressed air maintenance unit of the machine (1).
Only then connect the compressed air hose with the
compressed air source.
Check the manometer display (2). The operating pres-
sure must be between 5 and 5.5 bar.
If necessary readjust the operating pressure. To do this,
pull the adjusting screw (3) upwards and turn it carefully:
To increase the pressure, turn in a clockwise direction
To reduce the pressure, turn in an anti-clockwise
direction
Insert the power cable into the mains connection
socket (4) of the machine and connect it to the power
supply.