User Documentation
Setting up the machine
2516390000/03/07.201838
5.4 Insertingwire-endferrules
1. Set up the wire-end ferrule role so that clockwise unrolling
is ensured.
2. Turn the lock on the front ap to open it.
3. Swing the front ap to the side.
2.
1.
3.
Figure 5.6 Positioningthewire-endferrule
Figure 5.7 Threadingwire-endferrulesintothetransportunit
The transport bolt (gure 3.3, 2) in the transport unit must be
fully underneath. See also the sticker on the transport unit.
The transport bolt is pressed downwards by a spring.
If it is not fully down:
► Check if the transport bolt is blocked, and remove the
block if necessary.
► Push the wire-end ferrule belt into the transport unit
just until the lowest sheath latches in.
There must be no sheaths protruding downwards.
► Check for rm tting by pulling the wire-end ferrule
belt carefully.
► Close the front ap using the front ap lock.
► Roll up the loose wire-end ferrule belt.
5.5 Changingthewire-endferrulereel
► Turn the lock on the front ap to open it.
► Swing the front ap to the side.
► Press the transport bolt (gure 3.3, 2) fully upwards,
and pull the wire-end ferrule belt out of the transport
unit.
► See section 5.4.