When using the initiator/actuator terminal blocks of the A-series especially with other terminal blocks series 
or sizes or accessories the requirements for clearance and creepage distances according to table 1 of EN 
60079-7 must be observed. Regarding the use of covers, cross-connectors and end brackets the instructions 
of the manufacturer must be followed. 
No other wire sizes or types than the ones specified in instructions must be used. The 
terminal blocks must either be mounted next to another block of the same type and size or 
Essential Health and Safety Requirements:
Concerning ESRs this Schedule verifies compliance with the Annex III of ATEX directive only. By placing the 
product on the market, the manufacturer declares compliance with other relevant Directives, and all other 
safety related requirements including those of Annex II of this Directive.
Note: 
If smaller cross sections than the rated cross section are used, the belonging lower current has to be laid 
down in the IECEx/EC-Type Examination Certificate of the complete apparatus. 
Mounting instructions:
The initiator/actuator terminal blocks of the A-series are suitable for application in enclosures in atmospheres 
with flammable gases or combustible dust. For use in flammable gases these enclosures must satisfy the 
requirements according to IEC/EN60079-0 and IEC/EN60079-7. For use in combustible dust these 
enclosures must satisfy the requirements according to IEC/EN60079-0 and IEC/EN60079-31.
Regarding the use of accessories the instructions of the manufacturer must be followed.
Manually cut cross connections and cross connections with blank ends (ZQV´s 
≥ 20 poles) shall 
not be used.
If smaller conductor cross sections than the rated conductor cross sections are used, then the corresponding 
lower current shall be stated in the Certificate of the complete apparatus.
Schedule of Limitations:
The initiator/actuator terminal blocks of the A-series are suitable for use in enclosures in atmospheres with 
flammable gases or combustible dust. For flammable gases these enclosures must satisfy the requirements 
according to EN 60079-0 and EN 60079-7. For combustible dust the enclosure must satisfy the requirements 
according to EN 60079-0 and EN 60079-31. 
The enclosure shall be constructed to block all sun and UV light from affecting the terminal blocks. The 
terminal blocks shall be placed inside a suitable certified IP54 enclosure in type of protection “e” for gas 
atmosphere. For dust atmosphere the terminal blocks shall be mounted inside a suitable certified enclosure 
Under normal operating conditions the temperature rise of the terminal blocks is maximum 40 K, measured 
at the maximum permitted rated current. Due to the above mentioned, the terminal blocks may be used in 
apparatus of temperature classes T6..T1 as long as the terminal block ambient temperature range is not 
exceeded. No part of terminal block must exceed 110 °C under any condition. 
T6 (- 60°C ... +40 °C) 
T5 (- 60°C … +55 °C)
T4 (- 60°C ... +70 °C) 
For cross connection accessories current rating, resistance across the terminal please refer to the table 
under “Technical data” above. 