Approval/Certificate/Document of Conformity

(13)
SCHEDULE
(14)
to EU-Type Examination Certificate KEMA 09ATEX0168 X Issue No. 4
Page 3/3
Form 227A
Version 1 (2016-04)
(17)
Speci
fic
of
use
The NAMUR Pulse Isolator shall be installed in a controlled environment with suitable reduced pollution,
limited to pollution degree 2 or better.
The non-intrinsically safe circuits may only be connected to an overvoltage category I or II power source, as
defined in EN 60664-1.
If the NAMUR Pulse Isolator is installed in an explosive atmosphere where equipment protection level Gc is
required, it shall be installed in an enclosure in type of protection Ex n or Ex e, providing a degree of
protection of at least IP54. Cable entry devices and blanking elements shall fulfil the same requirement.
(18)
Essential Health and Safety Requirements
Covered by the standards listed at item (9).
(19)
Test documentation
As listed in Test Report No. NL/KEM/ExTR09.0087/03.
(20)
Cert
i
ficate history
Issue 1 - 213054600 Initial certificate
Issue 2 - 213256400 Corrected electrical data for the status relay
Issue 3 - 216740400 Update to new standards
Issue 4 - 223250800 Addition of *–P models and removal of EN 60079-26.